DH103A- 3-Way Pilot Operated Spool Valve
3-Way Pilot Operated Spool Valve. The DH103A/B/C Series Valves are used in normally closed or normally open directional control three way circuits requiring remote pilot actuation. The DH103 Series Valves are used to direct flow alternately from either side of a closed loop transmission for cooling or filtering. All external parts are zinc plated.
Operation (pressure at port 4 additive to spring).
DH103A (Normally Open)
• Neutral (Deactivated)
Port (3) open to port (2), port (4) is blocked.
• Activated with pilot pressure at port (1):
Port (3) open to port (4), port (2) blocked.
Note: There is an air breather vent plug in the end cap to allow for air pressure equalization in the spring chamber
DH103B (Normally Closed)
• Neutral (Deactivated)
Port (4) open to port (3), port (2) is blocked.
• Activated with pilot pressure at port (1):
Port (3) open to port (2), port (4) blocked.
DH103C (Normally Open)
• Neutral (Deactivated)
Port (3) open to port (2), port (4) is blocked.
• Activated with pilot pressure at port (1):
Port (3) open to port (4), port (2) blocked.
Description
- Manufacturer: Parker Hannifin
- Part Number: DH103A
- Description: 3-Way Pilot Operated Spool Valve ( Normally Open)
- Norminal Flow: 38 LPM
- Maximum Inlet Pressure: 240 Bar
- Leakage at 32 cSt: 50 cc/min at 240 Bar
- Cartridge Material: All parts steel. All operating parts hardened steel
- Operating Temperature Range/ Seals: -34 degC to +121 degC ( Nitrile)
- Fluid Compatibility/ Viscosity: Mineral-based or synthetic with lubricating properties at viscosities of 6 to 420 cSt
- Filtration: ISO-4406 18/16/13
- Cavity: C10-4
- Picture for illustration purposes only
- Download datasheet 3-way pilot operated spool valve DH103